不少客戶在運用灌膠機打商品時,因為技術(shù)紛歧樣,也許在打此外某類商品時需替換膠水,紛歧樣品種的膠水夾雜在一起,會起化學反映,會引起膠水中毒,致使灌出的商品達不到質(zhì)量需求。所以在替換膠水時必然要做好潔凈工作,下面由灌膠機廠家信華為我們作一下介紹:灌膠機清洗事項
Many customers use glue machine to make goods, because the technology is different, maybe they need to replace glue when they make some other goods. The glue mixed with different samples will cause chemical reaction, which will lead to glue poisoning, so that the products can not meet the quality requirements. So when replacing glue, we must do a good job of cleaning. Below, Xinhua, the glue machine manufacturer, will introduce the cleaning of glue machine.
1. 請與膠水供應商承認膠水潔凈劑。
1. Please acknowledge the glue cleaner with the glue supplier.
2. 封鎖AB料桶底部閥門。
2. Block the bottom valve of AB barrel.
3. 操作設備出膠,將殘留在膠閥,高壓鐵氟龍管,AB泵內(nèi)部的膠水打出,可查詢拜訪膠閥出膠口膠量改變,判斷內(nèi)部膠水已排空。
3. Operating equipment gum out, the glue remaining in the rubber valve, high-pressure ferrofluorine hose, AB pump out, you can inquire about the change of gum volume at the rubber valve outlet, judge that the internal glue has been emptied.
4. 封鎖設備總電源。
4. Blocking the general power supply of the equipment.
5. 拆開料桶底部膠管,翻開閥門,將料桶殘剩膠水排出。
5. Remove the rubber hose at the bottom of the barrel, open the valve and discharge the residual glue from the barrel.
6. 封鎖料桶底部閥門,將適量潔凈劑倒入料桶,將桶壁與桶底殘剩的膠水潔凈干凈。
6. Block the bottom valve of the barrel, pour a proper amount of cleaner into the barrel, and clean the remaining glue on the barrel wall and bottom.
7. 翻開料桶底部閥門,將污水排出,料桶不行有殘渣。
7. Open the bottom valve of the barrel and discharge the sewage. There is no residue in the barrel.
8. 拆下AB泵,將泵內(nèi)部膠水整理干凈(需受過拆裝泵操練人員操作此項)。
8. Remove the AB pump and clean up the glue inside the pump (it needs to be operated by the operator who has disassembled and assembled the pump).
9. 將干凈AB泵裝回原位,與料桶膠管從頭接上。
9. Install the clean AB pump back to its original position and connect it with the barrel hose from scratch.
10. 灌膠機替換高壓鐵氟龍管。
10. Replace high-pressure ferrofluorine hose with glue filler.
11. 倒入新膠水。
11. Pour in new glue.
12. 敞開設備,點動出膠3~5分鐘,承認膠水出膠正常。
12. Open the equipment and point out the glue for 3-5 minutes. Admit that the glue is normal.
13. 從頭分配AB膠水比例。
13. Distribution of AB glue ratio from scratch.
依照上面過程,將全部灌膠機潔凈干凈,再換膠水去灌膠凡是是不會呈現(xiàn)質(zhì)量疑問的。
According to the above process, all the glue-filling machines will be clean and clean, and then change the glue to glue-filling will not always present quality doubts.