打膠機不出膠及出膠硅酮膠速度慢的原因
打膠機不出膠實際上一般分三個方面,一是供氣的氣泵正常,二是供氣管路不漏氣,三是氣閥打開,這三個條件缺一不可,你可逐一檢查這些方面,下面來講講問題吧。
In fact, the failure of the glue dispenser is generally divided into three aspects: the first is that the air pump for gas supply is normal, the second is that the air supply pipeline is not leaking, and the third is that the air valve is open. These three conditions are indispensable. You can check these aspects one by one. Let's talk about the problems below.
打膠機不出膠的原因及解決辦法:
Reasons and solutions for glue failure of glue dispenser:
1,檢查氣源是否在0.60.8Mpa之間;
1. Check whether the air source is between 0.6 and 0.8MPa;
2,檢查觸摸屏中編輯功能菜單中的密封不使用是否打開;
2. Check whether the seal in the editing function menu in the touch screen is turned on when it is not in use;
3,檢查氣動開關(guān)是否阻塞;
3. Check whether the pneumatic switch is blocked;
4,檢查黑膠氣動開關(guān)與電磁閥動作是否正常;
4. Check whether the black glue pneumatic switch and solenoid valve operate normally;
5,檢查比例泵上的智能壓力表是否報警,范圍在7-35Mpa;
5. Check whether the intelligent pressure gauge on the proportional pump alarms, and the range is 7-35mpa;
6,檢查液壓站是否有壓力,如無壓力:1)清洗比例溢流閥2)檢查比例控制器是否通電或松動;
6. Check whether there is pressure in the hydraulic station. If there is no pressure: 1) clean the proportional overflow valve 2) check whether the proportional controller is powered on or loose;
7,清洗時是否能出白膠,如不出再檢查313膠管、旋轉(zhuǎn)接頭是否阻塞;
7. Check whether white glue can be released during cleaning. If not, check whether 313 rubber hose and rotary joint are blocked;
8,檢查一組比例泵下限傳感器IB233是否有信號,檢查二組比例泵IB407是否有信號;
8. Check whether there is a signal from the lower limit sensor ib233 of the first group of proportional pumps and whether there is a signal from the second group of proportional pumps ib407;
9,手動檢查掃描儀數(shù)值是否有正常。
9. Manually check whether the scanner value is normal.
The two-component glue applicator is slow in discharging silicone glue
使用硅酮結(jié)構(gòu)密封膠時,在打膠施工現(xiàn)場,經(jīng)常會遇到這些問題:打膠機出膠速度慢。產(chǎn)品在初次使用時,打膠機打膠過程中出現(xiàn)出膠速度過慢的現(xiàn)象,可能原因有三個:⑴A組分流動性差⑵壓盤過大⑶氣源壓力不夠。
When using silicone structural sealant, these problems are often encountered at the bonding construction site: the glue dispenser is slow in discharging glue. When the product is used for the first time, the glue dispensing speed of the glue dispenser is too slow during the glue dispensing process. There are three possible reasons: ⑴ poor fluidity of component a ⑵ too large pressure plate ⑶ insufficient air source pressure.
針對原因⑴或原因⑶,我們可以通過調(diào)整膠槍壓力來解決;針對原因⑵,訂購大口徑桶可以使問題得到解決。若出膠速度慢出現(xiàn)在正常使用過程中,則可能是混合芯和過濾網(wǎng)被堵塞,一旦發(fā)現(xiàn),就需要及時清理設(shè)備。
For the reason (1) or (3), we can solve it by adjusting the glue gun pressure; In view of the reason (2), ordering large-diameter barrels can solve the problem. If the glue delivery speed is slow during normal use, the mixing core and filter screen may be blocked. Once found, the equipment needs to be cleaned in time.
打膠機不出膠及出膠硅酮膠速度慢的原因便是以上了,我們都已經(jīng)明確找到原因了然后就應該根據(jù)原因做預防方案了,更多信息了解就來關(guān)注我們網(wǎng)站
http://dejiansw.cn吧!
The reason why the glue applicator does not produce glue and the speed of silicone glue is slow is the above. We have clearly found the reason, and then we should make preventive plans according to the reason. For more information, please pay attention to our website http://dejiansw.cn Come on!
上一篇:雙組份打膠機的使用您應當多注意
下一篇:雙組份打膠機的日常維護原來也分等級